Refrigerant Pressure Sensor / Switch: Service and Repair

REFRIGERANT PRESSURE SWITCH REMOVAL/INSTALLATION

1. Discharge the refrigerant from the system. (See REFRIGERANT CHARGING.)
2. Disconnect the negative battery cable.

CAUTION:  If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always
immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.

3. Remove the refrigerant pressure switch.
4. Install in the reverse order of removal.
5. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST.)

Refrigerant Pressure Switch Installation Note

1. Apply compressor oil to the O-ring and connect the joint.

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 249