mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2479 > < Electrical Specifications|Page 2476
Page 1
background image

Alternator: Component Tests and General Diagnostics

GENERATOR INSPECTION

Generator Warning Light

1. Verify that the battery is fully charged.

-

Charge if necessary.

2. Verify that the drive belt deflection/tension is within the specification. (See DRIVE BELT INSPECTION.)

-

Adjust if necessary.

3. Turn the ignition switch on and verify that the generator warning light comes on.

-

If the warning light does not illuminate, inspect the harness from ignition switch to generator warning light and from generator warning light to
3U terminal of PCM. If the generator warning light and harnesses are normal, replace the PCM.

4. Confirm that the generator warning light goes off after starting the engine.

-

If the generator warning light does not go off, inspect the on-board diagnostic system service code. (See ENGINE CONTROL SYSTEM
OPERATION INSPECTION.)

Generator

Voltage

1. Verify that the battery is fully charged.

-

Charge if necessary.

2. Verify that the drive belt deflection/tension is within the specification. (See DRIVE BELT INSPECTION.)

-

Adjust if necessary.

3. Turn off all electrical loads.
4. Turn the ignition switch to START and verify that the generator turns smoothly without any noise while the engine is running.

5. Measure the voltage at the terminals shown in the table.

-

If not as specified, disassemble and inspect the generator.

-

Headlights

-

Blower motor

-

Rear window defroster

Current

1. Verify that the battery is fully charged.

-

Charge if necessary.

Component Tests and General Diagnostics|Page 2479 > < Electrical Specifications|Page 2476