MX-6 L4-2184cc 2.2L SOHC Turbo F2 (1989)
Hose/Line HVAC: All Technical Service Bulletins
A/C - Receiver/Drier Inlet/Outlet Pipes Leak
Category U
Applicable Model/s 1988-'90 626/MX-6 w/A/C
Subject REFRIGERANT LEAK FROM INLET/OUTLET PIPE OF RECEIVER/DRIER TANK
Bulletin No.
008/90
Issued
2/19/90
Revised
DESCRIPTION
It has been found that the inlet or outlet pipe of the receiver/drier tank may develop a pinhole at the area shown below where the pipes are held by small
steel clips. This may result in a refrigerant leak.
Galvanic corrosion occurs between the aluminum pipe and the steel clip. This condition is more likely to develop in geographic areas that use large
amounts of salt on the roads and highways.
SERVICE HINTS
^
If a refrigerant leak is suspected, inspect the pipes of the receiver/drier tank.
^
The inlet/outlet pipes are available as a service part. Refer to the parts information in this bulletin.
^
In order to prevent galvanic corrosion from recurrence, place vinyl tape (insulator tape) between the steel clip and the aluminum pipe.
REPAIR PROCEDURE
1.
Charge the A/C system with small gas amount. Locate the pinhole on the pipes by using a gas leak detector.
2.
Remove the following parts:
a)
Right turn signal light
b)
Front grill
c)
Right headlight assembly
d)
Headlight bracket