KL MODEL GENERATOR

Removal/Installation

Caution:

-

Reversing the battery connections or using high-voltage testers will damage the rectifier.

-

Do not start the engine while the connector is disconnected from terminals L and S It can damage the generator.

-

When the battery cables are connected, touching the vehicle body with generator terminal B will generate sparks. This can cause personal
iniury, fire, and damage to the electrical components. Always disconnect the battery before performing the following operation.

Note:  Battery positive voltage is always present at generator terminal B when the battery is connected.

1. Fresh-air duct
2. Generator terminal B wire Inspect for damage and corrosion
3. Connector
4. Splash shield
5. Drive belt
6. Compressor
7. Generator