4. Inspect for an open or short circuit in the following wiring harnesses by probing the applicable sensor and SST (104 Pin Breakout Box) terminals

with ohmmeter leads.

Open circuit
-

GND circuit (CDCV connector terminal B and PCM connector terminal 18 through common connector)

-

Power circuit (CDCV connector terminal A and main relay connector terminal D)

Short circuit
-

GND circuit (CDCV connector terminal B and PCM connector terminal 18 through common connector to GND)

-

Power circuit (CDCV connector terminal A and main relay connector terminal D to GND)

5. Install the CDCV.
6. Connect the negative battery cable.