Protege L4-2.0L DOHC (2003)
Alternator: Testing and Inspection
Generator output voltage signal
-
PCM terminal: 30(+) - 103(-)
-
Oscilloscope setting: 2 V/DIV(Y), 5 ms/DIV(X), DC range
-
Vehicle condition: idle after warm up
Generator field coil control signal
-
PCM terminal: 53(+) - 103(-)
-
Oscilloscope setting: 0.2 V/DIV(Y), 2 ms/DIV(X), DC range
-
Vehicle condition: idle after warm up