Protege DX L4-1.6L DOHC (2000)
Condenser Fan Motor: Testing and Inspection
1. Disconnect the condenser fan connector.
2. Connect B+ to terminal A and ground to terminal B of the condenser fan and verify its operation.
-
If not as specified, replace the condenser fan.