Protege DX L4-1.6L DOHC (2000)
Technical Service Bulletin # 0700101
Date: 011221
A/C - Blower Unit Leaks Cold Air
Bulletin No: 07-001/01
Last Issued: 12/21/2001
Subject:
COLD AIR LEAKS AT BLOWER AND COOLING UNIT FOAM SEALS
APPLICABLE MODEL(S)/VINS
All 1999-2000 Proteges with VINs lower than JM1 BJ**** **399999
DESCRIPTION
Some customers may experience a cold air draft on the passenger side of vehicle in extremely cold regions. This condition may be caused by cold air
leaking from the foam seals at the cooling and/or blower units.
Customers having this concern should have their vehicle repaired using the following procedure.
INSPECTION PROCEDURE
1.
Verify customer concern.
2.
Adjust air intake door cable at blower unit.
-
For models equipped with manual REC/FRESH select lever, proceed to STEP 3.
-
For models equipped with electronic REC/FRESH switch, proceed to STEP 10.
3.
Remove glove box according to the Workshop Manual GLOVE COMPARTMENT REMOVAL/INSTALLATION (section 09-17 INTERIOR
TRIM).
4.
Set REC/FRESH select lever to FRESH position.
5.
Pull cable clip tang enough to release the cable.
6.
Pull cable down to align the set hole of the air intake link with the boss hole of the blower unit case.
7.
Secure cable back in clip.
8.
Move REC/FRESH select lever to REC then back to FRESH to confirm that the air intake door fully closes when in the FRESH position.