Protege DX L4-1.6L DOHC (2000)
Trunk Lamp Switch: Testing and Inspection
TRUNK COMPARTMENT LIGHT SWITCH INSPECTION
NOTE: Trunk compartment light switch has a built-in trunk lid lock.
1. Disconnect the trunk compartment light switch connector.
2. Inspect for continuity between the trunk compartment light switch terminal and a body ground using an ohmmeter.
-
If not as specified, replace the trunk lid lock.