mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Evaporative Emissions System > < Exhaust System - Excessive Sulfur Odors|Page 1936
Page 2
background image

Downstream HO2S Graphline Example 1 - 3

11. Using the following equation, calculate the value of ratio.

Equation
RATIO  = Upstream HO2S inversion / downstream HO2S Inversion

-

If the ratio is 2 or more or no downstream HO2S inversion, the WU-TWC is functioning properly.

-

If the ratio is less than 2, the WU-TWC is not functioning properly. Replace the WU-TWC.

Evaporative Emissions System > < Exhaust System - Excessive Sulfur Odors|Page 1936