Protege ES L4-1839cc 1.8L DOHC (1997)
Ignition Cable: Testing and Inspection
HIGH-TENSION LEAD INSPECTION
1. Measure the resistance of the high-tension leads.
Specification: 16kohms per 1.00m (3.28ft) @ 20°C (68°F)
2. If not as specified, replace the high-tension lead.