mazda Workshop Repair Guides

Mazda Protege ES L4-1839cc 18L DOHC Workshop Service and Repair Manuals

Electrical Specifications|Page 2834 > < Electrical Specifications|Page 2832
Page 1
background image

Shift Solenoid: Testing and Inspection

RESISTANCE INSPECTION 

1. Disconnect the negative battery cable.
2. Remove the battery and air cleaner component.
3. Disconnect the solenoid connector.
4. Measure the resistance between each terminal (A, B, C, D, G) and a ground.
5. If not as specified, replace the solenoid valve.
6. Connect the solenoid connector.
7. Install the air cleaner component and battery.
8. Connect the negative battery cable.

OPERATING INSPECTION 

1. Disconnect the negative battery cable.
2. Disconnect the solenoid connector.
3. Inspect the voltage at terminals A-G and listen for a "click" sound at all solenoid valves.
4. If the "click" is not heard, replace the solenoid valve.

OUTPUT DUTY INSPECTION 

1. Connect the (+) terminal of a dwell meter to terminal 4Z at the powertrain control module and the (-) terminal to a ground.
2. Set the dwell meter selector to the 4 cylinder position.
3. Engage the parking brake and use wheel chocks at the front and rear of the wheels.
4. Start the engine.
5. Depress the brake pedal firmly.

Electrical Specifications|Page 2834 > < Electrical Specifications|Page 2832