mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Sensors and Switches - Emission Control Systems > < Positive Crankcase Ventilation Valve|Testing and Inspection
Page 1
background image

EGR Control Module: Testing and Inspection

EGR Control Inspection (if equipped)

1. Verify that EGR valve operation (initial operation) sound is heard when the ignition switch is turned on.

-

If the operation sound is not heard, connect the SSTs (NGS tester) to DLC-2 and verify that the DTC No. P0401, P0402, P1496, P1497,
P1498 or P1499 is shown. Carry out troubleshooting of DTC No. P0401, P0402, P1496, P1497, P1498 or P1499.

2. Start the engine and run it at idle.
3. Select the SIMULATION TEST function on the NGS display.
4. Increase the step value of EGR valve from 0 to 40 using SEGRP PID.
5. Operate the EGR valve and inspect if the engine speed becomes unstable or the engine stalls.

-

If the engine speed will not change, perform the following:

1. Stop the engine.
2. Remove the EGR valve.
3. Connect the EGR valve connector.
4. Turn the ignition switch on.
5. Select the SIMULATION TEST function on the NGS display.
6. Increase the step value of EGR valve from 0 to 40 using SEGRP PID.
7. Inspect the EGR valve operation.

1. If the EGR valve is operating, clean the EGR valve and reinspect from Step 3.
2. If the EGR valve will not operate, replace the EGR valve and reinspect from Step 3.

6. Warm up the engine to normal operating temperature.
7. Select the PID/DATA MONITOR AND RECORD function on the NGS display.
8. Select the following PIDs.

-

SEGRP

-

RPM

-

VS

-

TP V

-

ECT V

9. Let the vehicle idle and verify that the SEGRP value is 0.

10. Put the vehicle in drive.
11. Depress the accelerator pedal and verify that the SEGRP value increases.

-

If the SEGRP value will not increase, inspect the VS, TP V and ECT V PIDs. (See PCM Inspection Using the SST (NGS tester).)

12. Stop the vehicle and verify that the SEGRP is returned 0.