Protege LX L4-1.6L DOHC (2000)
4. Inspect for an open or short circuit in the following wiring harnesses by probing the applicable sensor and SST (104 Pin Breakout Box) terminals
with ohmmeter leads.
Open circuit
-
Power circuit (VTCS solenoid valve connector terminal A and main relay connector terminal D through common connector)
-
GND circuit (VTCS solenoid valve connector terminal B and PCM connector terminal 19)
Short circuit
-
VTCS solenoid valve connector terminal A and main relay connector terminal D through common connector to GND
5. Reconnect the VTCS solenoid valve connector.
6. Reconnect the negative battery cable.