Protege LX L4-1.6L DOHC (2000)
Ignition Coil: Testing and Inspection
Igniter
-
Carry out spark test.
Ignition Coil Operation Inspection
1. Disconnect the negative battery cable.
2. inspect the ignition coilpower supply voltage (terminal 1A and 2A).
-
If not as specified, inspect the power supply system harness (ignition coil terminal 1A, 2A and ignition switch including short cord.).
Specification: B+
3. Inspect the ignition coil (terminal 1B and 2B) earth voltage.
-
If not as specified, inspect the ground system harness (Ignition coil terminal 1B, 2B and body ground.).
Specification: 0 V
4. Pull the ignition coil connector 1C and 2C out using a pin tool (terminal disconnector).
5. Remove the spark plug, high-tension lead and ignition coil.
ZM/1.6