mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 1218 > < Component Tests and General Diagnostics|Page 1216
Page 13
background image

Using SST (NGS Tester)

CAUTION:  The PCM terminal voltages vary with change in measuring conditions and vehicle conditions. Always carry out a total inspection of the
input systems, output systems, and PCM to determine the cause of trouble. Otherwise, a wrong diagnosis will be made.

PCM Inspection Using the SST (NGS tester)

NOTE:  

-

PIDs for the following parts are not available on this model. Go to the appropriate part inspection page.
-

ECT sensor (Water temperature sender unit)

-

CMP sensor

-

Main relay

1. Connect the NGS tester to the DLC-2.
2. Turn the ignition switch on.
3. Select the "PID/DATA MONITOR AND RECORD" function on the NGS display and press TRIGGER.
4. Select the appropriate PID on the NGS display and press START.
5. Measure the PID value.

-

If PID value is not within the specification, follow the instruction in Action column.

NOTE:  
-

Perform the SIMULATION TEST for the output device after PID/DATA measurement is completed.

-

The simulation items that are used in the system inspection are as follows.
-

A/C RLY

-

FAN2

-

FAN3

-

FP RLY

-

IACV

-

PRCV

-

PRGV

-

SEGRP

Component Tests and General Diagnostics|Page 1218 > < Component Tests and General Diagnostics|Page 1216