Protege LX L4-1489cc 1.5L DOHC MFI (1998)
Shift Interlock Solenoid: Testing and Inspection
SHIFT-LOCK ACTUATOR INSPECTION
1. Remove the rear console and front console.
2. Shift the selector lever to P position.
3. Turn the ignition switch to ON (engine OFF), and inspect for terminal voltage and continuity, referring to the chart. When inspecting for continuity
between terminal B (harness side) and ground, disconnect connector B.
4. If not as specified, repair the wiring harness and/or replace the shift-lock actuator.
5. Install the front console and rear console.
6. Verify correct operation of the shift-lock system.