mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Knock Sensor > < Non-Turbo|Page 2571
Page 1
background image

Ignition Switch: Testing and Inspection

Ignition switch "START" signal can be checked at ECU terminal 1C.  While cranking, terminal voltage should be approximately 12V.  With ignition
switch "ON," voltage should be 0V.

Knock Sensor > < Non-Turbo|Page 2571