mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

A/C - System Repair|Page 4328 > < A/C - System Repair
Page 2
background image

2.

CHECKING THE HEATER AMP CONTROL BOX

The time to check the heater amp control is when there is a problem with blower speed during heater or A/C operation. The heater amp control box
attaches onto the Logicon unit itself. Therefore, to reach the amp control box, you must remove the Logicon unit.

[Complaint] Blower fan does not go to full high speed or speed is too slow or operation is erratic.

[Check/Repair] Replace heater amp control as per Service Bulletin, Category 15, No .037/86.

3.

CHECKING THE AIR MIX ACTUATOR

The air mix actuator connector can be reached from under the dashboard, to the left of the center console. This actuator is a combination servo
motor and position sensor. The actuator "parks" at certain positions based on the position of the temperature control slide lever. If the links to the
actuator are bent, restricted or attached in the wrong position, the actuator may be prevented from stopping at the proper position, thus resulting in
internal damage. Proper positions can be verified as per workshop manual procedures. The G/W and Y wires alternately provide power and ground
from the Logicon to operate the servo. The remaining 3 wires send signals to the Logicon according to the position of the air mix temperature door.

[Complaint 1] A/C operates normally, but suddenly goes to heat. May return back to A/C again for no apparent reason (without touching controls). May
occur either intermittently or on a regular basis. Also may occur in opposite (heater to A/C).

[Check/Repair 1] Check air mix actuator, connector, actuator link. Be sure link and heater water valve do not restrict actuator movement. If above factors
check "good" but problem persists, problem may be internal. Replace the actuator with the new one.

[Complaint 2] Air volume is correct and comes out of proper opening, but is not heated properly or is always hot.

[Check/Repair 2] Check the following:

1.

Air mix actuator

2.

Rod links

3.

Water valve

4.

Clearance of wires

A/C - System Repair|Page 4328 > < A/C - System Repair