mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Heater Unit - Noise at 4,000 to 5,000 RPM|Page 4463 > < Heater Unit - Noise From the Water Flow|Page 4458
Page 1
background image

Heater Hose: All Technical Service Bulletins
Heater Unit - Noise at 4,000 to 5,000 RPM

Category

15
Applicable Model/s

1986-87 RX-7
Subject

WATER FLOW NOISE FROM HEATER
Bulletin No. 039/87
Issued

1/22/87

Revised

Heater Unit Noise Timing

DESCRIPTION

There is a possibility that noise can result from the water flow inside the heater unit. This noise can occur when the engine rotates at 4,000 to 5,000 RPM
with the temperature control lever approximately in the medium position.

Should the customer complain about such a noise, a service part is available to repair this problem. Use the procedures listed in this bulletin to eliminate
the noise.

Heater Hose Assembly

REPAIR PROCEDURE

Install an orifice in the (return side) heater hose as follows:

1.

Push the orifice into place so that it is seated evenly in the hose.. Do not install the orifice in a slanting position.

2.

Push the hose down 30 mm evenly on the fitting next to lower radiator hose.

Heater Unit - Noise at 4,000 to 5,000 RPM|Page 4463 > < Heater Unit - Noise From the Water Flow|Page 4458