Hose/Line HVAC: All Technical Service Bulletins
A/C - Buzzing Noise Repair

Category 16
Applicable Model/s 1987 RX-7 (ex. Turbo)
Subject CORRECTION & MODIFICATION OF A/C HOSE CLAMP
Bulletin No.

046/89

Issued

12/29/89

Revised

DESCRIPTION

Some 1987 RX-7 vehicles equipped with air conditioning systems may encounter a buzzing noise caused by the suction side of the A/C flexible hose
vibrating against the firewall.

When this condition occurs, check the retaining clamp (0000-67-A43A-6A) to see if it has lost its crimping ability. If it has, it can be easily corrected by
following the steps below:

1.

Loosen nut securing the clamp to the hose bracket.

2.

Crimp the clamp as shown in the illustration.

3.

Retighten nut.

This will give the clamp better crimping ability.