mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Metering Oil Pump Inspection|Page 1751 > < Metering Oil Pump Inspection
Page 2
background image

^

If not within the specification, replace the metering oil pump.

Resistance: 

400 ohms or less [20° C {68° F}]

Oil Nozzle Inspection 

1. Remove the oil nozzle.

2. Use a vacuum pump to apply a vacuum of 

66.5 kPa (0.68 kgf/cm2, 9.65 psi} or more on A of the oil nozzle and verify that vacuum holds:

^

If the vacuum drops 

2.66 kPa (0.027 kgf/cm2, 0.39 psi} or more in 1 min, replace the oil nozzle.

Oil Leakage Inspection 

1. Idle the engine and keep it.
2. Inspect for oil leakage along the mating surfaces of the metering oil pump and the front cover and where the oil pipe is connected.

^

If there is any malfunction, repair or replace.

Clogging Inspection 

1. Verify that there is no oil clogging in the following parts.

^

If there is any clogging, repair or replace.
-

Oil pipes

-

Oil nozzles

-

Metering oil pump connector bolts (connecting oil pipes and metering oil pump)

Metering Oil Pump Inspection|Page 1751 > < Metering Oil Pump Inspection