3. Inspect the following wiring harnesses for open or short circuit. (Continuity inspection)
Open circuit
-
If there is no continuity in the following wiring harnesses, there is an open circuit. Repair or replace the wiring harness.
-
ECT sensor terminal A and PCM terminal 2K
-
ECT sensor terminal B and PCM terminal 1U
Short circuit
-
If there is continuity at the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
-
ECT sensor terminal A and body ground
-
ECT sensor terminal A and power supply