Tribute 2WD L4-2.3L (2005)
Step 6 - 10
Step 11
Normal Operation
The roof opening panel module receives voltage on circuit (BR/O) when the ignition key is in the ACC or ON position. The roof opening panel module
is grounded through circuit (B). When the roof opening panel switch is pressed, circuit (B) and circuit (W) are connected for open/tilt down or circuit
(B) and circuit (V) are connected for close/tilt up. The roof opening panel module controls the roof opening panel motor by directing power and ground
on circuit (O) and circuit (R) to the motor.