mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4605 > < Initial Inspection and Diagnostic Overview|Page 4603
Page 1
background image

Power Distribution Module: Pinpoint Tests

PINPOINT TEST 1: DTCs B106E/B106F - SOLID STATE DRIVER DISABLED/MODULE DISABLED

Normal Operation

When a repetitive fault causing a circuit overload is detected on certain output circuits, the smart junction box (SJB) disables the circuit by removing
voltage, or ground, to the affected circuit. The circuit remains disabled until the fault is corrected and an on-demand self-test is run. When the on-demand
self-test has been run after all faults have been corrected, any DTCs related to the fault are cleared.

-

DTC B106E (Solid State Driver Disabled Due to Short Circuit) - sets when the SJB has disabled a circuit due to a repetitive fault causing a circuit
overload. For a complete list of corresponding DTCs, see Principles of Operation.

-

DTC B106F (Module Disabled Due to External Fault) - sets when one or more output functions are permanently disabled due to a repetitive circuit
overload fault. When DTC B106F is present, the SJB must be replaced after the fault condition has been corrected.

Possible Causes

-

Output circuit short to ground or voltage

-

SJB

Diagnostic Procedure

CAUTION:

-

Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

-

If DTC B106F is present and the SJB is to be replaced, the fault condition must be corrected first. Failure to correct the fault condition
first may cause damage to the new SJB, resulting in a repeat repair.

Step 1-Step 3

Initial Inspection and Diagnostic Overview|Page 4605 > < Initial Inspection and Diagnostic Overview|Page 4603