mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Brake Pedal Assy > < Component Bleeding|Page 3013
Page 2
background image

through the bleeder screws.

NOTE: Adequate 12-volt battery voltage is required during the system bleed. 

5. Using the pressure bleeder, apply 2 bars of pressure to the brake system.

6. Access the service bleed function on the scan tool.

7. While following the instructions on the scan tool, apply the brake pedal one full stroke and then completely release the brake pedal.

NOTE: The scan tool indicates when the service bleed procedure is not followed correctly. Continue with the service bleed procedure after correcting
the condition. Refer to the Service Bleed Error Codes chart. 

Service Bleed Error Codes

8. Continue to follow the instructions on the scan tool to complete the service bleed procedure.

Brake Pedal Assy > < Component Bleeding|Page 3013