mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Passenger Zone Valve Removal/Installation|Page 4254 > < Discharging And Recovery|Page 4249
Page 1
background image

Refrigerant Control Solenoid Valve: Service and Repair
Passenger Zone Valve Removal/Installation

-
PASSENGER ZONE VALVE REMOVAL/INSTALLATION - HYBRID

NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator. 

1. Recover the refrigerant. See  See: Service and Repair/Air Conditioning (A/C) System Evacuation And Charging.

2. Disconnect the passenger zone valve electrical connector.

3. Disconnect the 2 passenger zone valve fittings.

-

Discard the O-ring seals.

-

To install, tighten to 17 Nm {1.7 kgf-m, 13 ft-lbf}.

4. Remove the passenger zone valve bracket nut.

-

To install, tighten to 7 Nm {0.7 kgf-m, 62 in-lbf}.

5. Remove the passenger zone valve.

6. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil. See  See: Service and Repair/Refrigerant Oil Adding.

7. Evacuate, leak test and charge the refrigerant system. See  See: Service and Repair/Air Conditioning (A/C) System Evacuation And Charging

Passenger Zone Valve Removal/Installation|Page 4254 > < Discharging And Recovery|Page 4249