Tribute 4WD L4-2.3L Hybrid (2008)
Alignment: Testing and Inspection
Upon completion of an alignment, the position sensor must be calibrated:
1. Place the vehicle on a flat level surface with the transmission in PARK.
2. Place the steering wheel in the straight ahead position and remove hands from the wheel.
3. Connect the scan tool to the vehicle.
4. Turn the ignition key to the RUN position.
5. Using the scan tool, select the steering position sensor calibration and follow the scan tool instructions.
6. Clear any PSCM DTC's.
7. Turn the ignition key to the OFF position.
8. Road test the vehicle. If the steering wheel is not in the straight ahead position while driving on a flat road surface, check and adjust the alignment
as necessary.