CAUTION: When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining
clip area before separating from the tube or damage to the tube or connector retaining clip can occur. Apply clean engine oil to the end of the tube before
inserting the tube into the connector.

CAUTION: Fuel injection equipment is manufactured to very precise tolerances and fine clearance. It is essential that absolute cleanliness is observed
when working with these components or component damage can occur. Always install plugs to any open orifices or tubes.

CAUTION: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks. 

1. If servicing a liquid fuel tube quick connect coupling, release the fuel system pressure. See  See: Fuel Filter/Fuel Pressure Release/Service and

Repair.

2. Disconnect the battery ground cable. See  See: Starting and Charging/Battery/Service and Repair/Procedures/Battery Disconnect.

3. Release the quick connect coupling primary lock tab.

NOTE: Carefully release the lock tab to avoid breakage.

4. Rotate the primary lock tab to the fully unlocked position and squeeze the secondary lock tabs to release the locking mechanism.