6. Remove the evaporator outlet line fitting nut and disconnect the fitting.
-
Discard the O-ring seal and gasket seal.
-
To install, tighten to 15 Nm {1.5 kgf-m, 133 in-lbf}.
7. Remove the auxiliary evaporator outlet line fitting nut and disconnect the fitting.
-
Discard the O-ring seal and gasket seal.
-
To install, tighten to 15 Nm {1.5 kgf-m, 133 in-lbf}.
8. Remove the suction accumulator inlet fitting nut and disconnect the fitting.
-
Discard the O-ring seal and gasket seal.
-
To install, tighten to 15 Nm {1.5 kgf-m, 133 in-lbf}.
9. Remove the condenser-to-suction accumulator line.
10. To install, reverse the removal procedure.
-
Install new gasket seals and O-ring seals.
-
Lubricate the refrigerant system with the correct amount of clean PAG oil. See See: Heating and Air Conditioning/Service and
Repair/Refrigerant Oil Adding.
11. Evacuate, leak test and charge the refrigerant system. See See: Heating and Air Conditioning/Service and Repair/Air Conditioning (A/C) System
Evacuation And Charging.