Body Control Module: Description and Operation
Smart Junction Box (SJB)

-
SMART JUNCTION BOX (SJB) - HYBRID

Principles of Operation

NOTE:The time out for the battery saver relay and the accessory delay relay is 1 minute if the vehicle has less than 80 km (50 miles). For additional
information on the battery saver relay, see  See: Lighting and Horns/Testing and Inspection/Initial Inspection and Diagnostic Overview. For additional
information on the accessory delay relay, see - See: Windows and Glass/Windows/Description and Operation. Once the vehicle passes the approximate
mileage threshold of 80 km (50 miles), the time out for both relays will be the normal 10 minute time out, as described in the Owner's Literature.
The SJB is a multifunction control module that controls many of the vehicle systems. Several SJB functions utilize hardwired inputs and/or outputs. The
SJB controls the following hardwired functions, using the corresponding inputs and outputs.

In addition, the SJB is involved in other vehicle systems through communication over the controller area network (CAN). For a detailed list of SJB
network inputs and outputs, see  See: Module Configuration.
Some SJB parameters are programmable. Two types of programmable parameters are available: vehicle configuration and customer preference. See  
See: Module Configuration for additional information on programmable parameters.

Field-Effect Transistor (FET) Protection

The SJB utilizes a protective circuit strategy for many of its outputs (for example, the headlamp output circuit). Output loads (current level) are
monitored for excessive current (typically short circuits) and are shut down (voltage or ground provided by the module is turned off) when a fault is
detected. A continuous DTC is stored at that time for the fault.The circuit will reset after an ignition cycle or customer demand of the function (which
will switch the component on, causing the 30-minute battery saver timer to be energized). When an excessive circuit load occurs several times, the