Brake Bleeding: Service and Repair
Anti-Lock Brake System- Hydraulic System

Anti-Lock Brakes Bleed

BRAKE SYSTEM BLEEDING - HYDRAULIC SYSTEM 
Anti-Lock Brakes Bleed 

Note:  Carrying out the System Bleed function drives trapped air from the hydraulic control unit (HCU). Subsequent bleeding removes the air from
the brake hydraulic system to the bleeder screws.

Note:  The engine must be running to provide adequate voltage to the HCU module during the anti-lock control portion of the system bleed.

1. Connect the NGS Tester.
2. Start the engine and depress the brake pedal to half of the full travel position.
3. Access FUNCTION TEST mode and press the trigger to run the SYSTEM BLEED FUNCTION.
4. Manually bleed the brake hydraulic system.
5. Repeat the procedure carrying out a total of two NGS Tester cycles and two manual bleed cycles.

Manual Bleed

Manual Bleed

Brake system

Warning:  
^

Use of any other than the approved DOT 3 brake fluid will cause permanent damage to brake components and will render the brakes
inoperative. Failure to follow these instructions may result in personal injury.

Warning:  
^

Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with eyes. Wash hands thoroughly after handling. If brake fluid
contacts eyes, flush eyes with running water for 15 minutes. Get medical attention if irritation persists. If taken internally, drink water
and induce vomiting. Get medical attention immediately. Failure to follow these instructions may result in personal injury.

Caution:
^

Do not allow the brake master cylinder reservoir to run dry during the bleeding operation. Keep the brake master cylinder reservoir filled with the
specified brake fluid. Never reuse the brake fluid that has been drained from the hydraulic system.

Caution:
^

Brake fluid is harmful to painted and plastic surfaces. If brake fluid is spilled onto a painted or plastic surface, immediately wash it with water.

Note:
^

When any part of the hydraulic system has been disconnected for repair or a new component is installed, air may enter the system, causing spongy
brake pedal action. This requires the bleeding of the hydraulic system after it has been correctly connected.

Caution:
^

Be sure to check the brake fluid level in the brake master cylinder reservoir often. Do not let it run dry.

1. Fill the brake master cylinder reservoir with DOT 3 brake fluid.
2. Begin bleeding the system, going in order from the RH rear wheel, to the LH rear wheel, then to the RH front wheel and ending with the LH front

wheel.