Tribute LX 2WD V6-3.0L DOHC (2001)
Coupler HVAC: Service and Repair
A/C Coupler Spring
SPRING LOCK COUPLING
Disconnect
1. Recover the refrigerant.
2. Remove the A/C tube lock coupling clip.
3. Using the special tool, disengage the spring lock coupling fittings.
CAUTION: Do not use metal tools to remove the O-ring seals. They can cause axial scratches across the O-ring seal grooves resulting in
refrigerant leaks.
4. Remove the O-ring seals with a non-metallic tool.