mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Seats - Testing of New Orthopedic Design Backrest|Page 8073 > < Seats - Testing of New Orthopedic Design Backrest|Page 8071
Page 3
background image

The selected pressure is sustained as long as the ignition is switched on. A slow air leak will be compensated for by the supply pump. With ignition
off, the last cushion setting is retained in memory, and automatically adjusts the cushion to this setting after startup.

Air chambers 1-3 can be inflated in five stages (A-E) via the height selector "b". Depending on height adjustment, chambers 1-3 can be inflated
individually (position A, C or E) or chambers 1 and 2, or 2 and 3 together (position B or D). Refer also to "selectable height positions" chart.

FIGURE 4 - MODEL 126 11 RESERVOIR

FIGURE 5 - MODEL 201 11 RESERVOIR

2.

Air Supply to Cushions

Compressed air is delivered from the new version supply pump of the central locking system, which has an additional hose and electrical
connection.

After the ignition is switched on the pump delivers up to approximately 500 mbar to the reservoir (11, Figure 4 & 5) and' through the regulating
valve up to approximately 200 mbar (7, Figure 3) to the air cushions.
At an approximate pressure of 500 mbar, the supply pump switches off and comes on again when the pressure drops below 200 mbar, keeping
approximately 200-500 mbar supplied to the regulating valve (7).

When inflating the cushions, the pump keeps running to its cut-out point of approximately 500 mbar. After it shuts off, it comes on again for a short
while. These on/off cycles may repeat five times until the cushion air pressure is stabilized depending on the pressure adjustment "a". Although the pump
compensates for slow leaks, it will shut off after running continuously for 70 seconds, in case of a major leak. If the pump keeps cycling in short intervals
-(below 17 +/- 2 seconds), a leakage monitoring system adds up these cycles and will shut the pump off after a total of 31 cycles. This process is
cancelled when the ignition system is turned off and starts from the beginning. The summation of on/off cycles is also cancelled when one off cycle is
more than 17 +/- 2 seconds.

If the orthopedic backrest system and central locking system need pump action simultaneously, the central locking system has priority.

In the event that the pump is shut down after 70 seconds or 31 on/off cycles due to a leaking orthopedic backrest system, the function of the central
locking system is not affected.

C.Test Procedure

Technical Data

Cut-in pressure of pump

200-230 mbar

Seats - Testing of New Orthopedic Design Backrest|Page 8073 > < Seats - Testing of New Orthopedic Design Backrest|Page 8071