190E 2.3 (201.024) L4-2.3L (102.961) (1984)
Fuel Distributor: Description and Operation
Fuel Distributor with Electro-Hydraulic Actuator
As the volume of air entering the engine increases, the air flow sensor plate rises, the control plunger opens and fuel delivery to the injectors is increased.
When air flow decreases, the sensor plate and control plunger drop and less fuel is delivered to the injectors. When the engine is stopped (no air flowing
past sensor plate), the control plunger closes off the fuel distributor metering slot and no fuel is supplied to the injectors.