mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Fuel Filter > < Testing Fuel Pressure and Internal Leaktightness|Page 4326
Page 1
background image

Fuel Distributor: Testing and Inspection
Testing Continuity of Inductor In Fuel Distributor

Testing continuity of Inductor in fuel distributor 

Preceding work: 

Testing fuel pressures and internal leaktightness.   See: Testing Fuel Pressure and Internal Leaktightness

-

Detach connector at electrohydraulic actuator (Y1).
With lambda control: switch on ignition.  Detach oxygen sensor signal plug connection.

-

Unscrew fuel line at fuel distributor and seal with M10x1 plug.

-

Connect pressure hose (058) to fuel distributor and hold into measuring beaker. Special tool 103 589 00 21 05.

-

Detach fuel pump relay module and bridge contacts 7 and 8.  (Fuel pump running) Special tool 201 589 00 99 00.

-

Test inductor continuity
Specification: 130 - 150 cm3/min at minimum voltage of 11.5 V at fuel pump.

-

If specification is not reached, replace fuel distributor.

Fuel Filter > < Testing Fuel Pressure and Internal Leaktightness|Page 4326