mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Fuel - Test Sheet, Volume|Page 4185 > < Fuel - Test Sheet, Volume|Page 4183
Page 4
background image

plate is moved rapidly upward as the slow-moving control plunger lifts away from the control lever (1). During a slow upward movement, the
control plunger (2) must follow, maintaining a positive contact.

4  Check control plunger in fuel distributor for leaks.

Briefly fully depress air flow sensor plate and hold in this position; a slight leak quantity is permissible (illuminate with endoscope lamp, if
necessary).

 
 
Connecting pressure measuring device. 

1  Remove screw plug (arrow) on the lower chamber of the fuel distributor.

2  Connect hose line from connection "A" on lower chamber.

Use double fitting M8)( 1/M12 x 1.5, special tool 102 589 06 63 00 for this step.

3  Unscrew fuel line for start valve at fuel distributor.

4  Connect hose line from connection "B" at fuel distributor.

5  Position of valve screws:

a)  System pressure

Fuel - Test Sheet, Volume|Page 4185 > < Fuel - Test Sheet, Volume|Page 4183