mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Notes Concerning the Air/Fuel Mixture|Page 3298 > < Notes Concerning the Air/Fuel Mixture|Page 3296
Page 3
background image

Oxygen Sensor Connector Location

4. Disconnect the oxygen sensor connector.
5. While measuring, the indicated voltage should not oscillate. Note measured control value (should be between 2.1 - 4.8 V).

NOTE: If the voltage oscillates, the oxygen sensor plug is not disconnected or an other system fault is present.

 

6. Connect oxygen sensor plug. Voltage should oscillate.

NOTE: If the voltage is fixed (not oscillating), the oxygen sensor is disconnected or an other system fault is present.

7. Note mean (middle point) value.
8. Differance between the two readings (step 5 and 7) should be less then 0.8 V. If the differance is greater then 0.8 V, adjust control value. See:

Adjusting the Air/Fuel Mixture 

 

Notes Concerning the Air/Fuel Mixture|Page 3298 > < Notes Concerning the Air/Fuel Mixture|Page 3296