Removal and Installation of Vacuum Elements
Data
Permissible leaking of vacuum elements
20 mbar/min at 300 mbar vacuum
Plug-on length of connections
10-12 mm
Special tools
A. Vacuum element (37) for blend air flaps
Removal
1
Remove instrument panel
2
Pull vacuum line from vacuum element (37).
3
Unclip clamp (arrow) from connecting rod (a).
4
Unscrew both screws (73).
Installation
5
Fasten vacuum element to heater box and mount connecting rod.