mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Center Outlets|Page 7155 > < Center Outlets
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Defroster Outlet Flaps

Replacing The Defroster Flap Vacuum Element

1.

Remove the glove box.

2.

Pull off the vacuum lines (2, 3).

3.

Unclip rod (4) on lever (5).

4.

Depress the lock (arrow), and turn the vacuum element (38) to the left.

5.

Reinstall in reverse order.

Center Outlets|Page 7155 > < Center Outlets