mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

With Digital Tester (RIV Method)|Page 2052 > < With Digital Tester (RIV Method)|Page 2050
Page 1
background image

Injection Timing: Adjustments
Position Indicator RIV Method

ADJUSTING INJECTION TIMING (BEGIN OF DELIVERY) (POSITION INDICATOR RIV METHOD) - FOLLOWING CHECKUP

Testing and adjusting value

RI-adjusting value (indirect injection timing)  ...................................................................................................................................  -15° (after TDC)

Tightening torque

Closing plug on regulator (measuring point)  .........................................................................................................................  30-35 Nm (22-26 ft lb)

Special Tool

 

Note:  Check begin of delivery prior to adjustment.  See: Testing and Inspection/Position Indicator RIV Method

 
 

Adjusting 

1.  Mount holding bracket (01) on injection pump housing.

With Digital Tester (RIV Method)|Page 2052 > < With Digital Tester (RIV Method)|Page 2050