Speedometer Head: Testing and Inspection

Testing Electronic Speedometer model 124.034/036

A. Testing sensor with multimeter

Static test
-

Remove instrument cluster.   See: Instrument Cluster / Carrier/Service and Repair

-

Remove cover (a) on connector housing.

-

Check voltage with multimeter (003) between socket 4 (brown wire, ground) and socket 2 (black/violet wire with red dots, terminal 15). For this
check turn ignition/starter switch to position 2.

Specified value:  Battery voltage:  Use electrical connection set 201 589 00 99 00 for testing.

-

Measure resistance with multimeter (003) between socket 4 (brown wire, ground) and socket 3 (white wire, sensor lead).

Specified value: 2 k ohms ± 200 ohms. Use electrical connection set 201 589 00 99 00 for testing.

 

Dynamic test with multimeter

Connect multimeter (003):  Red test wire socket 3 (white wire, sensor wire). Black test wire to socket 4 (brown wire, ground) Use electrical
connection set 201 589 00 99 00 for testing.

-

Switch multimeter (003) on (range: volt)

-

Drive vehicle on dynamometer or on road. The voltage should increase continuously at increasing speed up to approx. 40 km/h > 1 V.

-

Close cover (a) on connector housing.

 
 
B. Testing sensor and speedometer with frequency generator

Diagram Information and Instructions|Page 10113 > < Diagram Information and Instructions|Page 10111