mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Vacuum Gauge/Economy Meter|Testing and Inspection|Page 10176 > < Diagram Information and Instructions|Page 10172
Page 1
background image

Vacuum Gauge/Economy Meter: Testing and Inspection

Testing economy driving gauge

 

-

Disconnect vacuum line at distributor (arrow).

-

Connect tester 201 589 13 21 00  to vacuum line at intake manifold.

-

Start engine.
Specification at idling speed: -0.4 to -0.6 bar. If the specification is not achieved, the vacuum line is fouled or leaking; clean or replace as
necessary.

-

Connect tester 201 589 13 21 00  between intake manifold and gauge. 

-

Gauge pointer moves to the left (1), specification at left stop:  >= -0.585 bar.

-

Increase idle speed until pointer of gauge is at start of red field (2).
Specification: approx. 0.4 bar.

-

If specified value or reading on gauge not reached check for leak in vacuum system of headlamp range control and/or air conditioner.

Note:   If a faulty vacuum unit at the transmission is found on vehicles with automatic transmission, oil may also be present in the gauge and in the

cable. Clean cable and replace gauge.

-

Disconnect tester 201 589 13 21 00.