Differential Pressure Regulator: Service and Repair

Fig. 11  Electro-Hydraulic Actuator

1.

Remove the electrical connector.

2.

With the ignition OFF relieve the fuel pressure by loosening the fuel line between the fuel distributor and the cold start valve.  Capture any fuel
running out with a cloth.

3.

Remove the electro-hydraulic actuator retaining screws.

4.

Remove the electro-hydraulic actuator.

5.

Replace o-rings and install in reverse manner.