3  Using the pin wrench, hold spring plate and slacken screw.
4  Remove spring plate.

Installation
5  Mount spring plate on compressor shaft and tighten nut to 16 ± 1.0 Nm.

6  Check clearance dimension with valve gauge or correct with spacer.
7  Fit V-belt and tension.
8  Install fan hub and fan.
9  Check operation of air conditioner (83-508).

 
 
Removal and installation of V-belt pulley 

Removal
1  Remove spring plate.

2  Remove snap ring from V-belt pulley (arrow) and knock V-belt pulley downwards with plastic hammer.
3  Install in reverse sequence.

Caution! 

If the same pulley is reinstalled, clean the friction surface on the pulley. If the friction surface is damaged (e.g. due to overheating),
replace pulley together with spring plate.

 