^ Cylinder #1 position (camshaft position sensor)
^ Combustion knock (Anti-knock sensor)
^ Full load (throttle valve switch)
^ Selection of ignition map (reference resistor)

Ignition Map

 
The EZL/AKR control unit compares information from these inputs with ignition maps for typical load and speed ranges which are stored in the
microcomputer. The optimal ignition timing for each operating condition is instantaneously determined from the stored maps and the power output stage
switches the primary current of the ignition coil between terminals 16 and 31 of the control unit. Furthermore, a TD (top dead center) reference signal is
provided to the CIS-E 5 control unit, tachometer, MAS control unit, on-board diagnostic connector, and the diagnostic socket. To further increase
operating reliability, a data exchange circuit has been added between the EZL/AKR control unit and the CIS-E 5 control unit. Information concerning the
coolant temperature, intake air temperature and the intake manifold absolute pressure is continuously compared by the control unit of each system.  
During cranking and up to approx. 450 RPM, the ignition timing is controlled via the segment edges (fixed) of the flywheel. After approx. 460 RPM has
been attained a transition from the fixed ignition timing to dynamic ignition timing (instantaneous, ignition map comparison) is made.
Various ignition characteristic curves are inhibited in the warm-up range depending on the coolant temperature in order to reach the normal operating
temperature as rapidly as possible.
When a full load signal is received from the throttle valve switch the control unit adapts a fixed full load ignition map characteristic. At temperatures
above approx. 203°F the ignition will be retarded to counter any further rise in temperature.

ANTI-KNOCK CONTROL

The knock control system can, depending on the intensity of the knock, retard the ignition point for an individual cylinder between 2.5° and 5° of
crankshaft angle per ignition cycle. The control unit can continue to retard the timing up to a maximum of 13.5° in cases of extreme knock due to fuel
condition, load, and excessively coolant temperatures.

MAXIMUM VEHICLE SPEED CONTROL

At a vehicle speed of approx. 155 mph the air/fuel mixture is leaned by the CIS-E 5 control unit. At the same time the EZL/AKR control unit retards the
ignition timing to 15° before TDC. Should the vehicle speed remain over 155 mph, the camshaft is advanced, reducing engine torque further. 

Ignition Shut Down Relay (For Antitheft) > < Diagram Information and Instructions|Page 5716