300CE (124.052) L6-3.2L (104.992) (1993)
5. Open bleeder valve SP until clear brake fluid flows out with no bubbles.
6. Close bleeder valve SP. Wait for pressure reservoir charging to finish (the charging pump and the return/pressure pump run audibly approx. 30
seconds and shut off).
7. Turn the engine off.
8. Disconnect the filling and bleeding equipment and top up the fluid level in the brake fluid reservoir using DOT 4 type brake fluid.