8. Remove drive shaft (11) from the bearing flange (4).
Examine drive shaft (11) and bearing bushes for signs of wear.
9. Use a screwdriver to press radial seal ring (13) out of the bearing flange (4).
34a Vickers/LUK pump
34b ZF pump
10. Remove locking ring (34a or 34b).
CAUTION: When removing locking ring, ensure that the housing bore is not damaged.
11. Remove flow control valve (32) and compression spring (30) from the pump housing (2).