02-5424/80

Additional Fuse Box for Blower Motor, Install

0.4 hr.

(after checking of fuse)

WORK INSTRUCTIONS

DATE:

March 1987                                                 NO. 206 GRP. 54

SUBJECT:

INSTALLING SEPARATE FUSE FOR BLOWER MOTOR MODEL 126 M.Y. 1986

FIGURE 1

1.

Disconnect the negative battery cable and cover the terminal.

2.

Attach bracket for auxiliary fuse box on left side of firewall (Figure 1).

3.

Mount auxiliary fuse box with attached input/output wires onto bracket (arrow, Figure 1).

4.

Route wires of auxiliary fuse box along the wiring harness through watertight grommet into the fuse/relay box. Secure with cable straps.

5.

Remove fuse carrier from fuse/relay box and connect 4 mm pink/green auxiliary wire from the auxiliary fuse having a 4.3 mm ring terminal to the
input side of fuse no. 16 (along with existing 4 mm pink/green wire).