300E (124.030) L6-3.0L (103.983) (1986)
FIGURE 3
If the lower fuse holder has receded (Figure 3), install a separate fuse holder with 30 amp fuse as described in Work Instructions 205 (Model 124) and
206 (Model 126).
FIGURE 4
Exchange all 25A fuses with solder tip fuses (Figure 4) the same time that the blower fuse is checked. These fuses have a higher temperature range than
the ones without solder tips.
Note:
When installing the auxiliary fuse holder for the blower motor, all other 25A fuses including the spare fuses, must also be exchanged with solder
tip fuses.
After the modification is complete, mark the main fuse box cover with a green dot.
Submit a warranty claim for parts and labor in the usual manner.
Parts Information
Part Name
Part Number
25 amp. solder
001 545 75 34
tip fuse
NOTE:
For part numbers for the auxiliary fuse holder see the attached W.I. 205 and/or 206.
Time Allowance
02-5423/70/80
25 amp. fuse, replace; and fuse carrier, check
0.3 hr.
(with maint. or repair work)
WORK INSTRUCTIONS
DATE:
March 1987 NO. 205 GRP. 54
SUBJECT:
INSTALLING SEPARATE FUSE FOR BLOWER MOTOR MODEL 124 M.Y. 1986